Factors leading to wall sticking in stainless steel reactors
Many problems have
been found in the production of the reactor, among which the stainless steel reactor wall stickiness is a frequent phenomenon, and the factors that lead to the wall stickiness are analyzed as follows:
First, the raw material factor is due to the excessive sulfate content in urea. When urea is added in the late stage of the polycondensation reaction of the resin, it is equivalent to adding a curing agent, which prompts the resin to quickly crosslink into a network structure. If it is not processed in time, the resin will be cured in the kettle. Therefore, standard industrial urea raw materials should be used in production to limit the sulfate content in urea to less than 0.01%.
Second, the balance of operation When the temperature, pressure and other glue making process indicators are unstable or fluctuate too much, the resin polycondensation reaction process is uneven, which is easy to cause sticky walls.Therefore, in the production operation, it should be slowly pressurized and heated.Generally, the water vapor of about 0.15 Mpa is kept for 2 to 3 minutes, and then the pressure is slowly increased and the temperature is raised.The ascending speed should be 0.1 to 0.15 Mpa per minute.
3. The temperature difference of the kettle wall The temperature of the cooling medium is too low or suddenly cooled, so that the temperature difference between the kettle wall and the material is too large, resulting in the glue wall contacting the kettle wall.Therefore, both heating and cooling should be carried out within a reasonable temperature difference range. Generally, the steam use temperature should be less than 180 °C, the temperature difference thermal impact should be less than 120 °C, and the cooling impact should be less than 90 °C.At the same time, pay attention to setting the appropriate inlet and outlet temperatures of the cooling medium to maintain a balanced operation.
4. Reaction temperature and time When the reaction solution temperature is lower than 80 °C, if ammonium chloride is used as a catalyst, the pH value cannot be displayed due to the fast reaction speed of ammonium chloride. After the temperature rises, the pH value drops quickly, the reaction speed is accelerated, and the polycondensation reaction is too strong, causing the gel to stick to the wall.In addition, the polycondensation reaction time is too long, the molecular weight of the resin is large, and the viscosity is too high, which is prone to sticky walls.Therefore, the temperature and time of the polycondensation reaction should be properly controlled during operation, and the reaction should be terminated in time.It is generally advisable to control the temperature of the reaction solution within ~ 95 ℃.