How to Handle Frequent Problems in Tube Condenser Operation
The formation of scale and dirt during the operation of the tube condenser is one of the troublesome problems. Due to its evaporation and vaporization working mechanism, it is easier to scale than other types of equipment. Therefore, regarding its protection, the main thing to think about is how to deal with its scaling. It is operated outdoors. The water on the surface of the pipe is prone to condensation due to continuous evaporation, high temperature and humidity, and is prone to corrosion. In order to solve this phenomenon, the upper and lower boxes of the equipment should ensure consistent galvanizing thickness. Because the water on the surface of the pipe continues to evaporate and is prone to scaling, it will greatly reduce the heat exchange efficiency of the equipment. For this reason, the following measures can be taken to solve the problem of scaling.
Use a cantilever type tube condenser: During the start and stop process of the host, due to the pressure difference and temperature difference in its serpentine tube, the pressure difference and temperature difference will cause the copper tube to produce an elastic straight effect. Since the expansion coefficients of copper and scale are very different, the cantilever type equipment has the function of automatic descaling. During the operation process, the refrigerant undergoes two-phase transformation and generates high-frequency vibration, so it is difficult to form scaling points, resulting in scale being unable to adhere to the tube wall; pre-film anti-scaling treatment should be carried out when manufacturing the tube condenser, which can effectively prevent dirt crystals from adhering to the surface of the copper tube; select a small number of continuous drainage devices The equipment can control the concentration multiple of calcium ions in the cooling circulating water within a specific range to effectively avoid the separation of scale; a precooler can also be set up to keep the surface evaporation temperature of the equipment below 50°C, and a large water volume intensive water distributor can be used to ensure that the surface of the tube is always covered with a water film and there are no dry spots. When the surface temperature of the heat exchange coil is lower than 50°C, the scale generated is loose and easy to wash away. When the surface temperature is higher than 50°C, the scale generated is solid and difficult to remove. Setting up a water baffle to prevent water from adhering to the higher-temperature condensation tube can effectively prevent equipment from scaling.
Performing daily maintenance and cleaning will greatly reduce the occurrence of scale and other problems in the tube condenser.