Methods to Reduce Condenser Resistance

       1. Use asymmetric plates and change the corrugated geometric structures on both sides of the plates to form a plate heat exchanger with hot and cold flow channels with different flow cross-sectional areas. The corner L on the side of the wide flow channel has a larger diameter. The heat transfer coefficient of an asymmetric device decreases slightly and the pressure drop is significantly reduced. When the flow rate of hot and cold media is relatively large, the use of asymmetric single-flow heat exchangers can reduce the plate area by 15% to 30% compared to the use of symmetrical single-flow heat exchangers.
       2. Use a thermal mixing plate with the same corrugated geometric structure on both sides of the plate. When the flow rate of hot and cold media is relatively large, using a thermal mixing plate can reduce the plate area compared to a symmetrical single-flow condenser. The diameters of the corner holes on the cold and hot sides of the hot mixing plate are usually equal. When the flow ratio of hot and cold media is too large, the pressure loss of the corner holes on the cold medium side is large. In addition, thermal mixing board design technology is not easy to achieve matching, which often results in limited board area savings. Therefore, it is not appropriate to use a thermal mixing plate when the flow ratio of hot and cold media is too large.
       3. When the flow rate of hot and cold media in the condenser is relatively large, a bypass pipe can be installed between the inlet and outlet of the equipment on the high flow side to reduce the flow into the equipment and reduce resistance. To facilitate adjustment, a regulating valve should be installed on the bypass pipe. This method should adopt a counter-flow arrangement to ensure that the temperature of the cold medium exiting the equipment is higher, ensuring that the temperature of the cold medium after the outlet merges can meet the design requirements.
       4. When the flow rate of hot and cold media is large, a multi-process combination arrangement can be used. More processes can be used on the small flow side to increase the flow rate and obtain a higher heat transfer coefficient. The high-flow side uses fewer processes to reduce condenser resistance. A mixed flow pattern appears in the multi-process combination, and the average heat transfer temperature difference is slightly lower. The fixed end plates and movable end plates of the equipment that adopts multi-process combination are equipped with pipes, so the workload during maintenance is heavy.
975 次

相关文档

Copy right © 2019 Wuxi Chemical Equipment Co., Ltd. All Rights Reserved Website Design: Wuxi Wangke