A condenser is a heat exchanger in which a vapour is cooled until it changes back into a liquid, releasing the latent heat it absorbed when it originally vaporised. That released heat is the condenser duty, and it must be removed to a cooling medium, most often cooling water, but sometimes air, chilled brine, a refrigerant or a process stream. The condensed liquid, called condensate, leaves the shell or tube side and is returned to the process or recovered for reuse.
In a distillation column the condenser handles both the overhead product vapour and the reflux; in a vacuum evaporator it condenses vapour at reduced pressure, allowing heat-sensitive materials to be evaporated without degrading. Condensation is far more effective than sensible cooling: condensing steam releases roughly 2,000 to 2,300 kJ per kilogram of condensate, against only a few kJ per kg for each degree of water cooling. Heat transfer area, not flow capacity, is therefore normally the governing design parameter, and drainage and fouling control directly determine performance.
Duty is the vapour mass flow rate multiplied by the latent heat of condensation at the operating pressure, plus any sensible heat if the vapour is superheated or the condensate subcooled. Latent heat depends strongly on pressure: saturated steam releases about 2,257 kJ/kg at atmospheric pressure, falling to roughly 2,000 kJ/kg at 10 bar. Solvent vapours follow the same pattern with very different magnitudes, and values must come from steam tables or property data for the actual mixture. Temperature approach is the difference between the vapour saturation temperature and the cooling medium outlet temperature; a tight approach means a small driving force and a larger area, but better heat recovery.
| Condensing medium | Condensing temperature | Typical application |
|---|---|---|
| Steam at 1 bar | About 100 degrees Celsius | Atmospheric column and evaporator duty |
| Steam at 3 bar | About 143 degrees Celsius | General process and stripping service |
| Refrigerant | Set by saturation pressure | Gas separation, cold traps, low boiling solvents |
| Ammonia | Set by saturation pressure | Refrigeration and ammonia condensation |
| Solvent vapour | Set by vapour pressure | Solvent recovery and vacuum distillation |
The shell-and-tube surface condenser is the workhorse of process plants. Vapour enters the shell, condenses on the outer surface of the tube bundle, and the condensate drains to a bottom outlet, while the cooling medium flows through the tubes. This keeps the condensing vapour on the shell side, where vapour velocity and the condensate drainage path are easier to control, and keeps the higher-pressure cooling water in the pressure-tight tube side. Common arrangements include fixed tube sheets with U-tubes, floating tube sheets with a gland, and one or two tube passes to raise water-side velocity and turbulence.
Because the fluids never mix, a surface condenser handles steam, mixed solvent vapours and flammable or toxic media. Layouts are horizontal or vertical, the latter where level control and complete shell drainage decide. Horizontal shells are easier to inspect and clean mechanically; vertical shells suit duties where condensate must be removed from a large vapour volume. A level controller or float trap on the condensate outlet is essential, because a flooded shell rapidly destroys the effective area and can cause a major upset.
Finned tube condensers are used where the cooling medium is air, or where a compact, low-weight arrangement is needed for clean vapour duties. Longitudinal or helical fins raise the surface area per unit volume, often by a factor of four to eight. In air-cooled service fan and fin fouling from dust or oil mist dominate the design, so fin material, spacing and corrosion protection need attention. Finned units are rarely used for condensing steam with dirty cooling water, because the fins trap scale and are impractical to clean.
Spiral plate condensers consist of formed plates welded to create a multi-pass channel. The thin plates and long narrow flow path give high area per unit volume and low hold-up, which suits condensing solvent vapours and vacuum duties where rapid condensate removal limits the approach. Plate condensers use a gasketed pack for primary duties at moderate pressure and can be opened for cleaning without tube removal. Their limitations are gasketed joints, lower pressure capability than welded designs, and the need for matched spare packs.
A direct contact condenser brings the cooling liquid into direct contact with the vapour, and the two streams leave as a single mixed liquid. This removes the heat transfer surface, so there is no scale inside the unit and no film to foul. The trade-off is that condensate and cooling medium are mixed, so the condensed product is diluted and cannot normally be recovered as a pure stream. The unit is mainly used where the condensate is a byproduct, or where the vapour is a toxic or flammable gas that must be scrubbed rather than condensed for reuse.
Three arrangements are common. The barometric condenser uses a vertical spray tower with a jet pump or ejector drawing vapour and cooling water into a barometric leg, where the mixture is cooled and the condensate flows to a hotwell. The jet type condenser uses a high-pressure water jet to create a vacuum and mix the vapour directly, and is common in pulp, paper and sugar evaporation duty. The tray type condenser distributes vapour through a cooling liquid pool over trays, giving good mass transfer but a large hold-up. Modern units often use ejector-assisted or mechanical vacuum systems, because a wet barometric leg depends on barometric head and is sensitive to flooding.
Material selection balances corrosion resistance, strength, heat transfer and cost. Carbon steel is the default for clean cooling water and general process service, used for the shell, tube sheets and channel. Stainless 304 or 316L is widely specified for solvent duties, product-contact service and cleaning-in-place service, with 316L preferred where chloride contamination is possible. Copper and cupro-nickel alloys are traditional choices for steam service and seawater cooling because of their excellent conductivity, but are avoided where ammonia, sulphur compounds or aggressive vapours are present.
Titanium is the standard answer for brackish water, seawater and chloride-contaminated circuits, though it must be kept free of iron contamination during fabrication. Graphite, as tubes or a graphite-lined vessel, handles highly corrosive media such as strong acids, wet chlorine and sulphuric acid duty. Glass-lined steel gives wide chemical resistance for acid and pharmaceutical service, with the caveat that the lining must not be cracked, chipped or thermally shocked. Hastelloy and Inconel are reserved for the most demanding combinations of temperature, pressure and corrosivity. Tube and shell materials are often deliberately different.
Sizing follows a fixed sequence. First the duty is fixed from the vapour flow rate and latent heat, including sensible heat for any inlet superheat. The condensing temperature follows from the vapour pressure. Cooling medium temperatures are then set from the cooling water supply and an allowable temperature rise, or from a chilled water system with a fixed return temperature. The log-mean temperature difference follows from the terminal differences, and because the condensing vapour is isothermal, the LMTD reduces to the arithmetic mean of the two end differences. The required area is then the duty divided by the overall heat transfer coefficient and the LMTD.
The U-value depends on the condensing film coefficient on one side, the convective coefficient and fouling factor on the cooling side, and the tube wall resistance. Design should use a fouled U-value, with the clean value recorded so operators can judge equipment condition. Shell diameter and nozzle sizes follow from the vapour and condensate loads.
| Design parameter | Typical value or guideline |
|---|---|
| Overall U-value, steam to water, fouled | 1,000 to 2,500 W per square metre per kelvin |
| Temperature approach, clean cooling water | 5 to 15 K |
| Subcooling of condensate | Normally avoided, up to 3 K where flashing follows |
| Area margin above calculated duty | 10 to 20 percent |
Selection is a multi-variable decision. The comparison below summarises the main trade-offs between the principal types and should be read with the vapour duty, the required condensing temperature, the cleanliness of the cooling medium and the need for a pure condensate. Where the condensate must be recovered at high purity, or the vapour is flammable, a surface condenser is usually mandatory. Where cooling water is dirty and the condensate is a waste stream, a direct contact condenser is often more economical. Shell-and-tube units are built to codes such as ASME Section VIII Division 1, TEMA for thermal performance detail, PED in Europe and GB/T 150 in China.
| Condenser type | Typical service | Main advantage | Main limitation |
|---|---|---|---|
| Shell-and-tube surface | Steam, solvent vapour, ammonia | Wide pressure and temperature range | Requires high quality cooling water |
| Direct contact, jet type | Atmospheric evaporation | No fouling surfaces, handles dirty vapour | Condensate is diluted |
| Barometric | Atmospheric evaporation | Simple, robust, low maintenance | Needs barometric head, large footprint |
| Finned tube | Air cooled, clean vapour | Compact, high area for air service | Fins trap dust, hard to clean |
| Spiral plate | Solvent vapour, vacuum duty | Low hold-up, fast drain-down | Limited size, forming limits |
| Plate | Condensing vapours, clean duty | Opens for cleaning, high efficiency | Gasket limits on pressure and temperature |
Design pressure is set by the condensing vapour pressure, the cooling medium pressure and the maximum possible pressure in either circuit, with a suitable margin. Shell-side nozzles for saturated steam service are normally specified a rating class above operating pressure. Relief devices protect the shell against a blocked-in steam condition, a cooling water valve failure that stops condensation, or a fire exposure. Where the condenser discharges to a flash drum, the relief scenario is a blocked-in shell, and the discharge must be routed to a safe location.
Vacuum breakers are fitted where the vessel can be exposed to full vacuum, for example during start-up before the ejector runs. Installation details decide whether the design works in practice. The condensate outlet must be sized generously and graded so liquid cannot back up into the shell, and the shell must be pitched as the vendor specified. A vent at the highest point lets non-condensable gas be swept out with the vapour. Instruments normally include shell pressure or differential pressure indication, condensate level indication and a low-flow alarm on cooling water.
A cooler handles sensible heat only and the stream stays in the same phase. A condenser changes the vapour phase, releasing much more latent heat. In a cooler the coefficient depends on flow velocity, in a condenser on the film.
Air has a low heat capacity and thermal conductivity, so air cooling needs far more area and is sensitive to ambient temperature. Water gives a higher overall coefficient and a smaller, cheaper exchanger. Air cooling is reserved for small duties and chillers condensing hot refrigerant.
Both are heat exchangers and, in a distillation column, they are often the same equipment, one duty producing vapour and the other condensing it. A reboiler boils the bottoms liquid, while the condenser removes that heat from the overhead vapour to return reflux.
Yes. A single shell may receive vapour from the column plus flash vapour from the reboiler, or separate circuits may discharge into a common condensate header. The designer must confirm that the mixture cannot create a flammable or toxic combination, and that shell and relief suit the duty.