What are the protection methods for the porcelain layer of the reactor?

What are the protection methods for the ceramic layer of the   reactor?The ceramic layer of the reactor is an important part of the enamel reactor. The thickness is about 0.8mm ~ 2mm. If it is used normally or poorly maintained, it is more likely to be damaged. Therefore, we need to protect it and increase the use time.
  1. Lift the reactor container with the ear seat or lifting ring to facilitate the moving position.Do not pass through manholes or connecting pipes through ropes.Do not lift the container at the manhole or clamp, be careful not to touch it easily, and do not roll and lift the container during operation.
  2. Pay attention to the process of sintering.The process of enamel firing is an important factor affecting the operation of the enamel reactor. If the process of enamel firing is not good, the quality of the enamel reactor will be affected. When used, it is easy to age and there is a problem of porcelain falling off.
  3. When handling the enamel reactor, the inside of the container should be equipped with protective measures or protective materials to protect the agitator or baffle.These can be removed until the device is installed.Protect the glass-lined porcelain layer with care when operating internally.
  4. Temperature control.During use, due to rapid temperature changes and large thermal expansion and contraction reactions, the reaction kettle ages out of porcelain.Therefore, in the process of operation and use, the temperature should not be suddenly high or low, or the reaction is too fast, and the operating temperature should be strictly controlled.
  Do not let it touch hard things, it is difficult to repair after damage, and the cost increases.