Condenser manufacturers share the method of condenser filling water leak test.
1. Before the water filling test, the accessories and other components welded to the condenser body should be completed.
2. Do not paint the welds related to the tightness test.
3. To use fresh water, the water temperature should not be less than 5 degrees Celsius, the chloride ion content in the water should not be greater than 25mg/L, and the water used for the aluminum floating roof test should not have a corrosive effect on aluminum.
4. The reinforcing ring should be fed with 0.1-0.2MPa of compressed air before the water filling test for weld leak detection.
5. During the water filling test: To strengthen the basic settlement observation, when we have an impermissible settlement situation, we should stop filling the water and wait until the treatment is completed before continuing the test.
6. During filling and discharging water:
(1) Open the breathing valve port and do not immerse the foundation. The water filling height is at a high operating level. When testing the strength of the condenser, keep it at this level for 48 hours and observe whether there is leakage in the condenser wall. If there is no leakage, it is qualified.
(2) If leakage is found, the correct treatment method is to discharge water in time, mark it before discharging water, and make the liquid level lower than the leakage point by about 300mm, and then repair welding.
7. When performing the strength and tightness test of the
condenser roof:
(1) The stability test shall be carried out by filling water to the designed high liquid level and discharging water.
(2) The water level should be one meter below the high liquid level, and then the water should be slowly filled and pressurized.When it rises to the test pressure, observe whether the filling top is deformed, and the non-leakage at the weld is qualified.