Negative Effects of Not Cleaning Spiral Plate Heat Exchanger in Time
With the accumulation of time, the helical plate heat exchanger will produce scale in the long-term heat exchange condition, resulting in the blockage of the heat exchanger, the heat exchange efficiency is low, and the original heat exchange effect cannot be achieved.inconvenience the user in many ways.
Scale plugs for a
long time, resulting in deterioration of heat exchange conditions. The over-rated temperature or local overheating of the heat transfer surface of the equipment may cause its cracks to burst and cause accidents.Energy consumption increases and results are not achieved.Dirt accumulation threatens the operation of the heat exchanger, and shortens its service life, making the heat exchanger face equipment downtime and maintenance. If it is serious, it is necessary to scrap the original equipment to replace its new equipment.
The spiral plate heat exchanger is in use.Due to improper operation of water treatment equipment.If the water quality control is not up to standard, the unqualified softened water is injected into the heating system, and the calcium, magnesium, and carbonate in the water are heated and decomposed into calcium carbonate and magnesium hydroxide precipitates, which are bonded to the heating surface of the equipment to form a hard scale.Due to the poor thermal conductivity of scale, the heat transfer efficiency of the equipment is reduced and the thermal energy is seriously wasted.This affects the efficiency of heating and has a serious negative impact on the heating unit.
The
equipment was not cleaned in time, and the scales in the water were incompletely filtered, resulting in the water outlet not being fully filtered and directly supplied to the user.Generally, domestic hot water units are basically used for bathing. Unfiltered water will have bad results on the human body and affect the human body if it is in contact with the skin for a long time.
Do not allow the helical plate heat exchanger to scale, strictly close the water quality during operation, be sure to carry out strict water quality inspection on the water in the system and the softened water in the softening tank, and then inject it into the pipeline network after passing.When the new system is put into operation, the equipment should be separated from the heating system, circulated for a period of time, and then the equipment should be integrated into the system to avoid impurities in the pipe network from entering the equipment.In the heating system, in addition to irregular cleaning of dirt and filters, cleanliness in the pipe network should be kept, not to block it.