What is Temperature Difference Stress of Condenser
The condenser is usually equipped with a series of baffles perpendicular to the tube bundle outside the tubes. At the same time, the connections between the tubes, the tubesheet and the shell are rigid. There are two fluids at different temperatures inside and outside the tube. When the temperature difference between the tube wall and the shell wall is large, due to the difference in thermal expansion between the two, a large temperature difference stress is generated, so that the tubes are twisted or the tubes are loosened from the tubesheet, which may damage the equipment.
Condenser In order to solve its temperature difference stress during operation, it must have a temperature difference compensation device during operation. Generally, when the temperature difference between the tube wall and the shell wall is more than 50 degrees, the equipment should have a temperature difference compensation device. However, the compensation device (expansion joint) can only be used when the temperature difference between the shell wall and the pipe wall is lower than 60 to 70°C and the shell side fluid pressure is not high. Generally, when the shell side pressure is higher than 0.6Mpa, the compensation ring is too thick and cannot easily expand and contract, thus losing the temperature difference compensation function, so other structures should be considered.